223 lines
6.1 KiB
Python
223 lines
6.1 KiB
Python
import asyncio
|
|
import ctypes
|
|
import sys
|
|
from ctypes import wintypes
|
|
from enum import IntEnum
|
|
from typing import Tuple
|
|
|
|
from ...exc import BleakError
|
|
|
|
if sys.version_info < (3, 11):
|
|
from async_timeout import timeout as async_timeout
|
|
else:
|
|
from asyncio import timeout as async_timeout
|
|
|
|
|
|
def _check_result(result, func, args):
|
|
if not result:
|
|
raise ctypes.WinError()
|
|
|
|
return args
|
|
|
|
|
|
def _check_hresult(result, func, args):
|
|
if result:
|
|
raise ctypes.WinError(result)
|
|
|
|
return args
|
|
|
|
|
|
# not defined in wintypes
|
|
_UINT_PTR = wintypes.WPARAM
|
|
|
|
# https://learn.microsoft.com/en-us/windows/win32/api/winuser/nc-winuser-timerproc
|
|
_TIMERPROC = ctypes.WINFUNCTYPE(
|
|
None, wintypes.HWND, _UINT_PTR, wintypes.UINT, wintypes.DWORD
|
|
)
|
|
|
|
# https://learn.microsoft.com/en-us/windows/win32/api/winuser/nf-winuser-settimer
|
|
_SET_TIMER_PROTOTYPE = ctypes.WINFUNCTYPE(
|
|
_UINT_PTR, wintypes.HWND, _UINT_PTR, wintypes.UINT, _TIMERPROC
|
|
)
|
|
_SET_TIMER_PARAM_FLAGS = (
|
|
(1, "hwnd", None),
|
|
(1, "nidevent"),
|
|
(1, "uelapse"),
|
|
(1, "lptimerfunc", None),
|
|
)
|
|
_SetTimer = _SET_TIMER_PROTOTYPE(
|
|
("SetTimer", ctypes.windll.user32), _SET_TIMER_PARAM_FLAGS
|
|
)
|
|
_SetTimer.errcheck = _check_result
|
|
|
|
# https://learn.microsoft.com/en-us/windows/win32/api/winuser/nf-winuser-killtimer
|
|
_KILL_TIMER_PROTOTYPE = ctypes.WINFUNCTYPE(wintypes.BOOL, wintypes.HWND, _UINT_PTR)
|
|
_KILL_TIMER_PARAM_FLAGS = (
|
|
(1, "hwnd", None),
|
|
(1, "uidevent"),
|
|
)
|
|
_KillTimer = _KILL_TIMER_PROTOTYPE(
|
|
("KillTimer", ctypes.windll.user32), _KILL_TIMER_PARAM_FLAGS
|
|
)
|
|
|
|
# https://learn.microsoft.com/en-us/windows/win32/api/combaseapi/nf-combaseapi-cogetapartmenttype
|
|
_CO_GET_APARTMENT_TYPE_PROTOTYPE = ctypes.WINFUNCTYPE(
|
|
ctypes.c_int,
|
|
ctypes.POINTER(ctypes.c_int),
|
|
ctypes.POINTER(ctypes.c_int),
|
|
)
|
|
_CO_GET_APARTMENT_TYPE_PARAM_FLAGS = (
|
|
(1, "papttype", None),
|
|
(1, "paptqualifier", None),
|
|
)
|
|
_CoGetApartmentType = _CO_GET_APARTMENT_TYPE_PROTOTYPE(
|
|
("CoGetApartmentType", ctypes.windll.ole32), _CO_GET_APARTMENT_TYPE_PARAM_FLAGS
|
|
)
|
|
_CoGetApartmentType.errcheck = _check_hresult
|
|
|
|
_CO_E_NOTINITIALIZED = -2147221008
|
|
|
|
|
|
# https://learn.microsoft.com/en-us/windows/win32/api/objidl/ne-objidl-apttype
|
|
class _AptType(IntEnum):
|
|
CURRENT = -1
|
|
STA = 0
|
|
MTA = 1
|
|
NA = 2
|
|
MAIN_STA = 3
|
|
|
|
|
|
# https://learn.microsoft.com/en-us/windows/win32/api/objidl/ne-objidl-apttypequalifier
|
|
class _AptQualifierType(IntEnum):
|
|
NONE = 0
|
|
IMPLICIT_MTA = 1
|
|
NA_ON_MTA = 2
|
|
NA_ON_STA = 3
|
|
NA_ON_IMPLICIT_STA = 4
|
|
NA_ON_MAIN_STA = 5
|
|
APPLICATION_STA = 6
|
|
RESERVED_1 = 7
|
|
|
|
|
|
def _get_apartment_type() -> Tuple[_AptType, _AptQualifierType]:
|
|
"""
|
|
Calls CoGetApartmentType to get the current apartment type and qualifier.
|
|
|
|
Returns:
|
|
The current apartment type and qualifier.
|
|
Raises:
|
|
OSError: If the call to CoGetApartmentType fails.
|
|
"""
|
|
api_type = ctypes.c_int()
|
|
api_type_qualifier = ctypes.c_int()
|
|
_CoGetApartmentType(ctypes.byref(api_type), ctypes.byref(api_type_qualifier))
|
|
return _AptType(api_type.value), _AptQualifierType(api_type_qualifier.value)
|
|
|
|
|
|
async def assert_mta() -> None:
|
|
"""
|
|
Asserts that the current apartment type is MTA.
|
|
|
|
Raises:
|
|
BleakError:
|
|
If the current apartment type is not MTA and there is no Windows
|
|
message loop running.
|
|
|
|
.. versionadded:: 0.22
|
|
|
|
.. versionchanged:: 0.22.2
|
|
|
|
Function is now async and will not raise if the current apartment type
|
|
is STA and the Windows message loop is running.
|
|
"""
|
|
if hasattr(allow_sta, "_allowed"):
|
|
return
|
|
|
|
try:
|
|
apt_type, _ = _get_apartment_type()
|
|
except OSError as e:
|
|
# All is OK if not initialized yet. WinRT will initialize it.
|
|
if e.winerror == _CO_E_NOTINITIALIZED:
|
|
return
|
|
|
|
raise
|
|
|
|
if apt_type == _AptType.MTA:
|
|
# if we get here, WinRT probably set the apartment type to MTA and all
|
|
# is well, we don't need to check again
|
|
setattr(allow_sta, "_allowed", True)
|
|
return
|
|
|
|
event = asyncio.Event()
|
|
|
|
def wait_event(*_):
|
|
event.set()
|
|
|
|
# have to keep a reference to the callback or it will be garbage collected
|
|
# before it is called
|
|
callback = _TIMERPROC(wait_event)
|
|
|
|
# set a timer to see if we get a callback to ensure the windows event loop
|
|
# is running
|
|
timer = _SetTimer(None, 1, 0, callback)
|
|
|
|
try:
|
|
async with async_timeout(0.5):
|
|
await event.wait()
|
|
except asyncio.TimeoutError:
|
|
raise BleakError(
|
|
"Thread is configured for Windows GUI but callbacks are not working."
|
|
+ (
|
|
" Suspect unwanted side effects from importing 'pythoncom'."
|
|
if "pythoncom" in sys.modules
|
|
else ""
|
|
)
|
|
)
|
|
else:
|
|
# if the windows event loop is running, we assume it is going to keep
|
|
# running and we don't need to check again
|
|
setattr(allow_sta, "_allowed", True)
|
|
finally:
|
|
_KillTimer(None, timer)
|
|
|
|
|
|
def allow_sta():
|
|
"""
|
|
Suppress check for MTA thread type and allow STA.
|
|
|
|
Bleak will hang forever if the current thread is not MTA - unless there is
|
|
a Windows event loop running that is properly integrated with asyncio in
|
|
Python.
|
|
|
|
If your program meets that condition, you must call this function do disable
|
|
the check for MTA. If your program doesn't have a graphical user interface
|
|
you probably shouldn't call this function. and use ``uninitialize_sta()``
|
|
instead.
|
|
|
|
.. versionadded:: 0.22.1
|
|
"""
|
|
allow_sta._allowed = True
|
|
|
|
|
|
def uninitialize_sta():
|
|
"""
|
|
Uninitialize the COM library on the current thread if it was not initialized
|
|
as MTA.
|
|
|
|
This is intended to undo the implicit initialization of the COM library as STA
|
|
by packages like pywin32.
|
|
|
|
It should be called as early as possible in your application after the
|
|
offending package has been imported.
|
|
|
|
.. versionadded:: 0.22
|
|
"""
|
|
|
|
try:
|
|
_get_apartment_type()
|
|
except OSError as e:
|
|
# All is OK if not initialized yet. WinRT will initialize it.
|
|
if e.winerror == _CO_E_NOTINITIALIZED:
|
|
return
|
|
else:
|
|
ctypes.windll.ole32.CoUninitialize()
|